Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Nephrol ; 25(1): 61, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38383316

RESUMO

Fabry disease (FD) is an uncommon, X-linked, lysosomal storage disease that causes defects in the glycosphingolipid metabolic pathway due to deficient or absent lysosomal α-galactosidase (α-Gal A) activity. This leads to the accumulation of globotriaosylceramide (GL-3) within lysosomes in a wide range of cells, including endothelial, cardiac, renal, and corneal cells, and consequently, the progressive appearance of clinical symptoms in target organs. Enzyme replacement therapy (ERT), which involves the exogenous supplementation of α-Gal A enzyme and has been successfully administered for treating FD.Here, we report a case of a 37-year-old male with complaints of recurrent proteinuria and ventricular septal thickening. A renal biopsy revealed vacuolization and foamy changes in podocytes, and the presence of myelin-like bodies and zebra bodies. The white blood cell α-Gal A activity was very low, while the Lyso-GL-3 level was high. Additionally, genetic analysis revealed a gene variant c.902G > A p. Arg301Gln. The patient was diagnosed with FD, and subsequently received intravenous ERT with a dose of Agalsidase α (0.2 mg/kg, 17.5 mg every 2 weeks). Currently, the values of proteinuria and ventricular septum thickness remain stable during the 6-month follow-up. Initiating ERT at an early age can effectively decrease the deposition of GL-3, attenuate the progressive clinical manifestations of FD, and provide greater long-term benefits.


Assuntos
Doença de Fabry , Masculino , Humanos , Adulto , Doença de Fabry/complicações , Doença de Fabry/tratamento farmacológico , Doença de Fabry/genética , Terapia de Reposição de Enzimas , alfa-Galactosidase/genética , alfa-Galactosidase/uso terapêutico , Proteinúria/tratamento farmacológico , Proteinúria/etiologia , Rim/patologia , Ventrículos do Coração/patologia
2.
Nat Nanotechnol ; 19(3): 319-329, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38135719

RESUMO

Electronic devices for recording neural activity in the nervous system need to be scalable across large spatial and temporal scales while also providing millisecond and single-cell spatiotemporal resolution. However, existing high-resolution neural recording devices cannot achieve simultaneous scalability on both spatial and temporal levels due to a trade-off between sensor density and mechanical flexibility. Here we introduce a three-dimensional (3D) stacking implantable electronic platform, based on perfluorinated dielectric elastomers and tissue-level soft multilayer electrodes, that enables spatiotemporally scalable single-cell neural electrophysiology in the nervous system. Our elastomers exhibit stable dielectric performance for over a year in physiological solutions and are 10,000 times softer than conventional plastic dielectrics. By leveraging these unique characteristics we develop the packaging of lithographed nanometre-thick electrode arrays in a 3D configuration with a cross-sectional density of 7.6 electrodes per 100 µm2. The resulting 3D integrated multilayer soft electrode array retains tissue-level flexibility, reducing chronic immune responses in mouse neural tissues, and demonstrates the ability to reliably track electrical activity in the mouse brain or spinal cord over months without disrupting animal behaviour.


Assuntos
Encéfalo , Elastômeros , Camundongos , Animais , Estudos Transversais , Eletrodos , Encéfalo/fisiologia , Neurônios/fisiologia
3.
Plant Phenomics ; 5: 0078, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37539074

RESUMO

The organ-specific critical nitrogen (Nc) dilution curves are widely thought to represent a new approach for crop nitrogen (N) nutrition diagnosis, N management, and crop modeling. The Nc dilution curve can be described by a power function (Nc = A1·W-A2), while parameters A1 and A2 control the starting point and slope. This study aimed to investigate the uncertainty and drivers of organ-specific curves under different conditions. By using hierarchical Bayesian theory, parameters A1 and A2 of the organ-specific Nc dilution curves for wheat were derived and evaluated under 14 different genotype × environment × management (G × E × M) N fertilizer experiments. Our results show that parameters A1 and A2 are highly correlated. Although the variation of parameter A1 was less than that of A2, the values of both parameters can change significantly in response to G × E × M. Nitrogen nutrition index (NNI) calculated using organ-specific Nc is in general consistent with NNI estimated with overall shoot Nc, indicating that a simple organ-specific Nc dilution curve may be used for wheat N diagnosis to assist N management. However, the significant differences in organ-specific Nc dilution curves across G × E × M conditions imply potential errors in Nc and crop N demand estimated using a general Nc dilution curve in crop models, highlighting a clear need for improvement in Nc calculations in such models. Our results provide new insights into how to improve modeling of crop nitrogen-biomass relations and N management practices under G × E × M.

4.
Lab Chip ; 22(7): 1286-1296, 2022 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-35266462

RESUMO

Electrode-based impedance and electrochemical measurements can provide cell-biology information that is difficult to obtain using optical-microscopy techniques. Such electrical methods are non-invasive, label-free, and continuous, eliminating the need for fluorescence reporters and overcoming optical imaging's throughput/temporal resolution limitations. Nonetheless, electrode-based techniques have not been heavily employed because devices typically contain few electrodes per well, resulting in noisy aggregate readouts. Complementary metal-oxide-semiconductor (CMOS) microelectrode arrays (MEAs) have sometimes been used for electrophysiological measurements with thousands of electrodes per well at sub-cellular pitches, but only basic impedance mappings of cell attachment have been performed outside of electrophysiology. Here, we report on new field-based impedance mapping and electrochemical mapping/patterning techniques to expand CMOS-MEA cell-biology applications. The methods enable accurate measurement of cell attachment, growth/wound healing, cell-cell adhesion, metabolic state, and redox properties with single-cell spatial resolution (20 µm electrode pitch). These measurements allow the quantification of adhesion and metabolic differences of cells expressing oncogenes versus wild-type controls. The multi-parametric, cell-population statistics captured by the chip-scale integrated device opens up new avenues for fully electronic high-throughput live-cell assays for phenotypic screening and drug discovery applications.


Assuntos
Técnicas de Cultura de Células , Semicondutores , Fenômenos Eletrofisiológicos , Microeletrodos , Óxidos
5.
Lab Chip ; 20(17): 3239-3248, 2020 08 26.
Artigo em Inglês | MEDLINE | ID: mdl-32756639

RESUMO

The synaptic connections between neurons are traditionally determined by correlating the action potentials (APs) of a pre-synaptic neuron and small-amplitude subthreshold potentials of a post-synaptic neuron using invasive intracellular techniques, such as patch clamping. Extracellular recording by a microelectrode array can non-invasively monitor network activities of a large number of neurons, but its reduced sensitivity usually prevents direct measurements of synaptic signals. Here, we demonstrate that a newly developed complementary metal-oxide-semiconductor (CMOS) nanoelectrode array (CNEA) is capable of extracellularly determining direct synaptic connections in dense, multi-layer cultures of dissociated rat neurons. We spatiotemporally correlate action potential signals of hundreds of active neurons, detect small (∼1 pA after averaging) extracellular synaptic signals at the region where pre-synaptic axons and post-synaptic dendrites/somas overlap, and use those signals to map synaptic connections. We use controlled stimulation to assess stimulation-dependent synaptic strengths and to titrate a synaptic blocker (CNQX: IC50 ∼ 1 µM). The new capabilities demonstrated here significantly enhance the utilities of CNEAs in connectome mapping and drug screening applications.


Assuntos
Axônios , Neurônios , Potenciais de Ação , Animais , Óxidos , Ratos , Semicondutores , Sinapses
6.
Nat Biomed Eng ; 4(2): 232-241, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31548592

RESUMO

Current electrophysiological or optical techniques cannot reliably perform simultaneous intracellular recordings from more than a few tens of neurons. Here we report a nanoelectrode array that can simultaneously obtain intracellular recordings from thousands of connected mammalian neurons in vitro. The array consists of 4,096 platinum-black electrodes with nanoscale roughness fabricated on top of a silicon chip that monolithically integrates 4,096 microscale amplifiers, configurable into pseudocurrent-clamp mode (for concurrent current injection and voltage recording) or into pseudovoltage-clamp mode (for concurrent voltage application and current recording). We used the array in pseudovoltage-clamp mode to measure the effects of drugs on ion-channel currents. In pseudocurrent-clamp mode, the array intracellularly recorded action potentials and postsynaptic potentials from thousands of neurons. In addition, we mapped over 300 excitatory and inhibitory synaptic connections from more than 1,700 neurons that were intracellularly recorded for 19 min. This high-throughput intracellular-recording technology could benefit functional connectome mapping, electrophysiological screening and other functional interrogations of neuronal networks.


Assuntos
Eletrofisiologia/instrumentação , Eletrofisiologia/métodos , Potenciais da Membrana , Nanotecnologia/instrumentação , Neurônios/fisiologia , Animais , Células Cultivadas , Estimulação Elétrica , Microeletrodos , Ratos , Sinapses/fisiologia
7.
IEEE J Solid-State Circuits ; 55(9): 2567-2582, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33762776

RESUMO

CMOS microelectrode arrays (MEAs) can record electrophysiological activities of a large number of neurons in parallel but only extracellularly with low signal-to-noise ratio. Patch clamp electrodes can perform intracellular recording with high signal-to-noise ratio but only from a few neurons in parallel. Recently we have developed and reported a neuroelectronic interface that combines the parallelism of the CMOS MEA and the intracellular sensitivity of the patch clamp. Here, we report the design and characterization of the CMOS integrated circuit (IC), a critical component of the neuroelectronic interface. Fabricated in 0.18-µm technology, the IC features an array of 4,096 platinum black (PtB) nanoelectrodes spaced at a 20 µm pitch on its surface and contains 4,096 active pixel circuits. Each active pixel circuit, consisting of a new switched-capacitor current injector--capable of injecting from ±15 pA to ±0.7 µA with a 5 pA resolution--and an operational amplifier, is highly configurable. When configured into current-clamp mode, the pixel intracellularly records membrane potentials including subthreshold activities with ∼23 µVrms input referred noise while injecting a current for simultaneous stimulation. When configured into voltage-clamp mode, the pixel becomes a switched-capacitor transimpedance amplifier with ∼1 pArms input referred noise, and intracellularly records ion channel currents while applying a voltage for simultaneous stimulation. Such voltage/current-clamp intracellular recording/stimulation is a feat only previously possible with the patch clamp method. At the same time, as an array, the IC overcomes the lack of parallelism of the patch clamp method, measuring thousands of mammalian neurons in parallel, with full-frame intracellular recording/stimulation at 9.4 kHz.

8.
Acc Chem Res ; 51(3): 600-608, 2018 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-29437381

RESUMO

Electrode technology for electrophysiology has a long history of innovation, with some decisive steps including the development of the voltage-clamp measurement technique by Hodgkin and Huxley in the 1940s and the invention of the patch clamp electrode by Neher and Sakmann in the 1970s. The high-precision intracellular recording enabled by the patch clamp electrode has since been a gold standard in studying the fundamental cellular processes underlying the electrical activities of neurons and other excitable cells. One logical next step would then be to parallelize these intracellular electrodes, since simultaneous intracellular recording from a large number of cells will benefit the study of complex neuronal networks and will increase the throughput of electrophysiological screening from basic neurobiology laboratories to the pharmaceutical industry. Patch clamp electrodes, however, are not built for parallelization; as for now, only ∼10 patch measurements in parallel are possible. It has long been envisioned that nanoscale electrodes may help meet this challenge. First, nanoscale electrodes were shown to enable intracellular access. Second, because their size scale is within the normal reach of the standard top-down fabrication, the nanoelectrodes can be scaled into a large array for parallelization. Third, such a nanoelectrode array can be monolithically integrated with complementary metal-oxide semiconductor (CMOS) electronics to facilitate the large array operation and the recording of the signals from a massive number of cells. These are some of the central ideas that have motivated the research activity into nanoelectrode electrophysiology, and these past years have seen fruitful developments. This Account aims to synthesize these findings so as to provide a useful reference. Summing up from the recent studies, we will first elucidate the morphology and associated electrical properties of the interface between a nanoelectrode and a cellular membrane, clarifying how the nanoelectrode attains intracellular access. This understanding will be translated into a circuit model for the nanobio interface, which we will then use to lay out the strategies for improving the interface. The intracellular interface of the nanoelectrode is currently inferior to that of the patch clamp electrode; reaching this benchmark will be an exciting challenge that involves optimization of electrode geometries, materials, chemical modifications, electroporation protocols, and recording/stimulation electronics, as we describe in the Account. Another important theme of this Account, beyond the optimization of the individual nanoelectrode-cell interface, is the scalability of the nanoscale electrodes. We will discuss this theme using a recent development from our groups as an example, where an array of ca. 1000 nanoelectrode pixels fabricated on a CMOS integrated circuit chip performs parallel intracellular recording from a few hundreds of cardiomyocytes, which marks a new milestone in electrophysiology.


Assuntos
Linfócitos B/metabolismo , Fenômenos Eletrofisiológicos , Miócitos Cardíacos/metabolismo , Nanopartículas/química , Neurônios/metabolismo , Animais , Linhagem Celular , Membrana Celular/química , Membrana Celular/metabolismo , Eletrodos , Humanos
9.
Front Plant Sci ; 8: 1517, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28928757

RESUMO

Precise quantification of plant nitrogen (N) nutrition status is essential for crop N management. The concept of critical N concentration (Nc) has been widely used for assessment of plant N status. This study aimed to develop a new winter wheat Nc dilution curve based on leaf area duration (LAD). Four field experiments were performed on different cultivars with different N fertilization modes in the Yangtze River basin and Yellow River basin in China. Results showed that the increase in LAD with increasing cumulative thermal time took the shape of an "S" type curve; whereas shoot N concentration decreased with increasing LAD, according to a power function. Both LAD and shoot N concentration increased with increasing N application. The new LAD based Nc dilution curve was determined and described as Nc = 1.6774 LAD-0.37 when LAD > 0.13. However, when LAD ≤ 0.13, Nc was constant and can be calculated by the equation when LAD = 0.13. The validation of Nc dilution curve with dataset acquired from independent experiments confirmed that N nutrition index (NNI) predictions based on the newly established Nc dilution curve could precisely diagnose N deficiency at different plant growth stages. The integrated N nutrition index (NNIinte), which was obtained by the weighted mean of NNI, was used to estimate shoot N concentration, shoot dry matter, LAD, and yield using regression functions. The linear relationships between NNIinte and these growth variables were well correlated. These results provided enough evidence that the new LAD-based Nc dilution curve could effectively and precisely diagnoses N deficiency in winter wheat crops.

10.
Nat Nanotechnol ; 12(5): 460-466, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28192391

RESUMO

Developing a new tool capable of high-precision electrophysiological recording of a large network of electrogenic cells has long been an outstanding challenge in neurobiology and cardiology. Here, we combine nanoscale intracellular electrodes with complementary metal-oxide-semiconductor (CMOS) integrated circuits to realize a high-fidelity all-electrical electrophysiological imager for parallel intracellular recording at the network level. Our CMOS nanoelectrode array has 1,024 recording/stimulation 'pixels' equipped with vertical nanoelectrodes, and can simultaneously record intracellular membrane potentials from hundreds of connected in vitro neonatal rat ventricular cardiomyocytes. We demonstrate that this network-level intracellular recording capability can be used to examine the effect of pharmaceuticals on the delicate dynamics of a cardiomyocyte network, thus opening up new opportunities in tissue-based pharmacological screening for cardiac and neuronal diseases as well as fundamental studies of electrogenic cells and their networks.


Assuntos
Diagnóstico por Imagem , Cardiopatias/metabolismo , Ventrículos do Coração/metabolismo , Potenciais da Membrana , Miócitos Cardíacos/metabolismo , Animais , Eletrodos , Cardiopatias/patologia , Cardiopatias/fisiopatologia , Ventrículos do Coração/patologia , Miócitos Cardíacos/patologia , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...